Validation of a Device for Registering Orthotic Wearing Time during the Laboratory Climate Tests on Normal Volunteers
N. Fallahian *1, F. Tabatabaei, M. Rahgozar, R. VahabKashani, M. Bahrami
1- , N.Fallahian@gmail.com
Abstract:   (21937 Views)

Laboratory instrumentation of orthoses and prostheses can be used to objectively gain accurate information. In this study the measurement of orthosis wearing time during laboratory climate tests with normal volunteers were accomplished to determine the validity and reliability of the device for registering orthotic wearing time that was designed and fabricated in Iran. Orthosis wearing time is an important factor in orthotic treatment for spine disorders. A reliable and objective System for measuring orthosis wearing time currently is still lacking in Iran. After Developing such a device, our objective was to test the accuracy and validity of the device, Made in Iran which was designed to register spinal orthosis wearing time. The device had a force sensor mounted on a thoracolumbosacral orthosis pad to recorded orthosis wearing time. In an interval of 1 hour 5 Normal volunteers tested the device using a CASH orthosis. They donned the orthosis for a few minutes and doffed it meanwhile they recorded the time using a standard chronometer into the "Orthotic Wearing" form. After gaining the data one sample t-test was performed on all orthosis wearing-time intervals as recorded by the system and by the time tables filled by each of the 5 testers using a chronometer. The tests yielded 100 sensor trigger-events that is 50 times of orthotic wear (t=2.21, P=0.032). As indicated by the t-test analysis, the device for registering orthotic wearing time had accurately quantified the orthosis wearing-time intervals during the laboratory climate tests with normal volunteers.

Keywords: Orthosis Wearing Time
Full-Text [PDF 499 kb]   (4328 Downloads)    
Article Type: Original Research | Subject: Veterans or Handicapped Health
Received: 2008/10/18 | Accepted: 2014/06/24 | Published: 2014/06/24
Send email to the article author

Add your comments about this article
Your username or Email:

CAPTCHA
User comments
Comment sent by Largest Discount Christian Louboutin Black Marychal 100mm For Sale on 2014/08/30
deleted include the bare minimum half headwear, substituted for obtainable suffering full auto accident lids.
Largest Discount Christian Louboutin Black Marychal 100mm For Sale http://caddissports.com/CG/Largest-Discount-Christian-Louboutin-Black-Marychal-100mm-For-Sale-0425.chtml


XML     Print


Download citation:
BibTeX | RIS | EndNote | Medlars | ProCite | Reference Manager | RefWorks
Send citation to:

Fallahian N, Tabatabaei F, Rahgozar M, VahabKashani R, Bahrami M. Validation of a Device for Registering Orthotic Wearing Time during the Laboratory Climate Tests on Normal Volunteers. Iran J War Public Health 2009; 1 (1) :74-90
URL: http://ijwph.ir/article-1-11-en.html


Rights and permissions
Creative Commons License This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License.
Volume 1, Issue 1 (2009) Back to browse issues page
مجله طب جانباز Iranian Journal of War and Public Health
Persian site map - English site map - Created in 0.05 seconds with 31 queries by YEKTAWEB 4549