بررسی تاثیر فیت مناسب و نامناسب سوکت بر میزان مصرف انرژی در افراد دچارقطع عضو زیر زانو یک طرفه
The effect of appropriate and inappropriate prosthetic socket fit on the energy expenditure in unilateral below knee amputees
سلامت جانبازان يا معلولان
Veterans or Handicapped Health
پژوهشی اصيل
Original Research
<p dir="RTL" style="text-align: justify;"><strong>اهداف:</strong> افراد قطع عضو اندام تحتانی باید برای دستیابی به راهرفتن طبیعیتر تلاش بیشتری کنند که این امر منجر به افزایش مصرف انرژی در این افراد در مقایسه با افراد سالم میشود. هدف از انجام این مطالعه، بررسی تاثیر فیت سوکت بر میزان مصرف انرژی هنگام راهرفتن در افراد دچار قطع عضو اندام تحتانی بود.</p>
<p dir="RTL" style="text-align: justify;"><strong>مواد و روشها:</strong> این پژوهش نیمهتجربی در سال 1394، روی 9 فرد قطع عضو زیر زانوی مراجعهکننده به مرکز بنیاد جانبازان تهران که بهروش نمونهگیری دردسترس انتخاب شده بودند، انجام شد. اجرای مطالعه در دو مرحله، یکی در شرایط فیت نامناسب و دیگری در شرایط فیت مناسب صورت گرفت. برای ارزیابی فیت سوکت از پرسشنامه مقیاس سهبعدی قطع عضو و مقیاس راحتی سوکت استفاده شد. میزان انرژی مصرفی آزمودنیها نیز با استفاده از شاخص مصرف فیزیولوژیک اندازهگیری شد. تجزیه و تحلیل دادهها بهکمک نرمافزار <span dir="LTR">SPSS 19</span> و توسط آزمون آماری <span dir="LTR">T</span> زوجی صورت گرفت.</p>
<p dir="RTL" style="text-align: justify;"><strong>یافتهها:</strong> میانگین سرعت راهرفتن افراد (0.001=<span dir="LTR">p</span>) و میزان <a name="OLE_LINK32"></a><a name="OLE_LINK31">شاخص فیزیولوژیک </a>مصرف انرژی (0.019=<span dir="LTR">p</span>) با فیت نامناسب و با فیت مناسب دارای اختلاف آماری معنیدار بود، اما تفاوت ضربان قلب حین استراحت و حین راهرفتن در دو مرحله مذکور معنیدار نبود (0.093=<span dir="LTR">p</span>).</p>
<p dir="RTL" style="text-align: justify;"><strong>نتیجهگیری:</strong> افراد قطع عضو اندام تحتانی، با داشتن فیت مناسب انرژی مصرفی کمتری را متحمل میشوند و کارآیی آنها در راهرفتن بهبود مییابد.</p>
<p dir="RTL"></p>
<p dir="RTL"></p>
<p dir="LTR" style="text-align: justify;"><strong>Aims:</strong> Persons with lower-limb amputations need to achieve more natural gait through more effort, leading to an increase in the energy consumption in them compared to the healthy persons. The aim of this study was to investigate the effects of the socket fit on gait energy consumption level in persons with lower limb amputations.</p>
<p dir="LTR" style="text-align: justify;"><strong>Materials & Methods:</strong> In the semi-experimental study, 9 persons with below knee amputation, referred to Tehran Veterans Foundation Center, were studied in 2015. The subjects were selected via available sampling method. The study was consisted of two steps, including improper fit and proper fit conditions. The socket fitting was assessed by the trinity amputation scale and the socket comfort scale. The level of energy consumption of the subjects was measured by the physiological cost index. Data was analyzed by SPSS 19 software using paired T test.</p>
<p dir="LTR" style="text-align: justify;"><strong>Findings:</strong> Mean values of persons’ gait speed (p=0.001) and the physiological cost index (p=0.019) with improper fit and proper fit were significantly different. Nevertheless, the difference between gait heart beat and resting heart beat at two steps was not significant (p=0.093).</p>
<p dir="LTR" style="text-align: justify;"><strong>Conclusion:</strong> Lower energy consumption can be achieved in persons with lower-limb amputations through the utilization of a proper fit, leading to a better gait.</p>
<p dir="LTR"></p>
<p dir="LTR"></p>
<p></p>
قطع عضو زیر زانو, راحتی سوکت, مصرف انرژی
Amputation, Socket Comfort, Energy Transfer
189
194
http://ijwph.ir/browse.php?a_code=A-10-1334-1&slc_lang=fa&sid=1
Jahani
عطیه
جهانی
at.jahani@uswr.ac.ir
15300319475328460013394
15300319475328460013394
Yes
Orthotics & Prosthetics Department, Rehabilitation Faculty, University of Social Welfare and Rehabilitation Sciences, Tehran, Iran
گروه ارتوز و پروتز، دانشکده توانبخشی، دانشگاه علوم بهزیستی و توانبخشی، تهران، ایران
Gh.
Aminiyan
غلامرضا
امینیان
15300319475328460013395
15300319475328460013395
No
Orthotics & Prosthetics Department, Rehabilitation Faculty, University of Social Welfare and Rehabilitation Sciences, Tehran, Iran
گروه ارتوز و پروتز، دانشکده توانبخشی، دانشگاه علوم بهزیستی و توانبخشی، تهران، ایران
M.R.
Safari
محمدرضا
صفری
15300319475328460013396
15300319475328460013396
No
Orthotics & Prosthetics Department, Rehabilitation Faculty, University of Social Welfare and Rehabilitation Sciences, Tehran, Iran
گروه ارتوز و پروتز، دانشکده توانبخشی، دانشگاه علوم بهزیستی و توانبخشی، تهران، ایران
H.
Nabavi
هدی
نبوی
15300319475328460013397
15300319475328460013397
No
Ergonomics Department, Rehabilitation Faculty, University of Social Welfare and Rehabilitation Sciences, Tehran, Iran
گروه ارگونومی، دانشکده توانبخشی، دانشگاه علوم بهزیستی و توانبخشی، تهران، ایران
M.R.
Mardani
محمدعلی
مردانی
15300319475328460013398
15300319475328460013398
No
Orthotics & Prosthetics Department, Rehabilitation Faculty, University of Social Welfare and Rehabilitation Sciences, Tehran, Iran
گروه ارتوز و پروتز، دانشکده توانبخشی، دانشگاه علوم بهزیستی و توانبخشی، تهران، ایران