<?xml version="1.0" encoding="utf-8"?>
<journal>
<title>Iranian Journal of War and Public Health</title>
<title_fa>طب جانباز</title_fa>
<short_title>Iran J War Public Health</short_title>
<subject>Medical Sciences</subject>
<web_url>http://ijwph.ir</web_url>
<journal_hbi_system_id>153</journal_hbi_system_id>
<journal_hbi_system_user>ijwph</journal_hbi_system_user>
<journal_id_issn>2008-2622</journal_id_issn>
<journal_id_issn_online>2008-2630</journal_id_issn_online>
<journal_id_pii></journal_id_pii>
<journal_id_doi>10.58209/ijwph</journal_id_doi>
<journal_id_iranmedex></journal_id_iranmedex>
<journal_id_magiran></journal_id_magiran>
<journal_id_sid></journal_id_sid>
<journal_id_nlai></journal_id_nlai>
<journal_id_science></journal_id_science>
<language>en</language>
<pubdate>
	<type>jalali</type>
	<year>1393</year>
	<month>8</month>
	<day>1</day>
</pubdate>
<pubdate>
	<type>gregorian</type>
	<year>2014</year>
	<month>11</month>
	<day>1</day>
</pubdate>
<volume>6</volume>
<number>5</number>
<publish_type>online</publish_type>
<publish_edition>1</publish_edition>
<article_type>fulltext</article_type>
<articleset>
	<article>


	<language>fa</language>
	<article_id_doi></article_id_doi>
	<title_fa>مقایسه میزان حرکت پیستونی در دو نوع پروتز پی‌تی‌بی سوپراکندیلار در افراد قطع عضو زیر زانو یک‌طرفه؛ مطالعه موردی</title_fa>
	<title>Comparison of the Piston Movement between two Supracondylar PTB Prostheses in Transtibial Amputees A Case Report Study</title>
	<subject_fa>توانبخشی جانبازان يا معلولان</subject_fa>
	<subject>Rehabilitation of Veterans or Handicapped</subject>
	<content_type_fa>گزارش مورد/سری</content_type_fa>
	<content_type>Case/Series Report</content_type>
	<abstract_fa>&lt;p class=&quot;MsoNormal&quot; dir=&quot;rtl&quot; style=&quot;margin-bottom: 0.0001pt line-height: normal direction: rtl unicode-bidi: embed&quot;&gt;&lt;font face=&quot;tahoma, arial, helvetica, sans-serif&quot;&gt;&lt;b&gt;&lt;span lang=&quot;FA&quot;&gt;اهداف:&lt;/span&gt;&lt;/b&gt;&lt;span lang=&quot;FA&quot;&gt; &lt;/span&gt;&lt;span lang=&quot;FA&quot;&gt;قطع عضو زیر زانو شایع‌ترین محل قطع عضو اندام تحتانی است.&lt;/span&gt;&lt;span lang=&quot;FA&quot; style=&quot;font-size: 14pt&quot;&gt; &lt;/span&gt;&lt;span lang=&quot;FA&quot;&gt;سیستم تعلیق پروتز زیر زانو، از اجزای مهم آن به‌شمار می‌رود.&lt;/span&gt;&lt;span lang=&quot;FA&quot; style=&quot;font-size: 14pt&quot;&gt; &lt;/span&gt;&lt;span lang=&quot;FA&quot;&gt;هدف از این مطالعه، مقایسه میزان حرکت پیستونی در 2 نوع
پروتز &quot;پی‌تی‌بی سوپراکندیلار مرسوم&quot; و &quot;پی‌تی‌بی سوپراکندیلار با
تعلیق پنوماتیک&quot; در یک فرد قطع عضو زیر زانو یک‌طرفه بود.&lt;/span&gt;&lt;span dir=&quot;ltr&quot;&gt;&lt;/span&gt;&lt;span lang=&quot;FA&quot; dir=&quot;ltr&quot; style=&quot;font-size: 11pt&quot;&gt;&lt;span dir=&quot;ltr&quot;&gt;&lt;/span&gt; &lt;/span&gt;&lt;span lang=&quot;FA&quot;&gt;&lt;o:p /&gt;&lt;/span&gt;&lt;/font&gt;&lt;/p&gt;

&lt;p class=&quot;MsoNormal&quot; dir=&quot;rtl&quot; style=&quot;margin-bottom: 0.0001pt line-height: normal direction: rtl unicode-bidi: embed&quot;&gt;&lt;font face=&quot;tahoma, arial, helvetica, sans-serif&quot;&gt;&lt;b&gt;&lt;span lang=&quot;FA&quot;&gt;بیمار و روش‌ها:&lt;/span&gt;&lt;/b&gt;&lt;span lang=&quot;FA&quot;&gt; این مطالعه به
روش شبه‌تجربی ساده، در کلینیک توانبخشی گروه ارتوز و پروتز دانشکده علوم توانبخشی
ایران، با دعوت به همکاری از یک فرد قطع عضو زیر زانوی یک‌طرفه در سال 1393 انجام
شد. بعد از مراحل طراحی و ساخت بالشتک هوا، میزان حرکت پیستونی یک بار در پروتز پی‌تی‌بی
سوپراکندیلار مرسوم و سپس در پروتز پی‌تی‌بی سوپراکندیلار با تعلیق پنوماتیک&lt;/span&gt;&lt;span dir=&quot;ltr&quot;&gt;&lt;/span&gt;&lt;span lang=&quot;FA&quot; dir=&quot;ltr&quot; style=&quot;font-size: 11pt&quot;&gt;&lt;span dir=&quot;ltr&quot;&gt;&lt;/span&gt; &lt;/span&gt;&lt;span lang=&quot;FA&quot;&gt;با روش عکس‌برداری و استفاده از نشانگر طی 4 مرحله آزمون
بارگذاری ثابت شامل تحمل وزن کامل، تحمل وزن نیمه، بدون تحمل وزن و اعمال بار 30
نیوتنی اندازه‌گیری شد.&lt;o:p /&gt;&lt;/span&gt;&lt;/font&gt;&lt;/p&gt;

&lt;p class=&quot;MsoNormal&quot; dir=&quot;rtl&quot; style=&quot;margin-bottom: 0.0001pt line-height: normal direction: rtl unicode-bidi: embed&quot;&gt;&lt;font face=&quot;tahoma, arial, helvetica, sans-serif&quot;&gt;&lt;b&gt;&lt;span lang=&quot;FA&quot;&gt;یافته‌ها:&lt;/span&gt;&lt;/b&gt;&lt;span lang=&quot;FA&quot;&gt; میانگین جابه‌جایی
عمودی نشانگرها در پروتز مرسوم در حالت بدون تحمل وزن، ±15میلی‌متر بود، در حالی
که این مقدار در پروتز پنوماتیک کاهش پیدا کرد (5±میلی‌متر). میانگین جابه‌جایی
عمودی نشانگرها بعد از اعمال وزنه 3کیلوگرم در پروتز مرسوم 20±میلی‌متر بود که در
پروتز پنوماتیک کاهش پیدا کرد (10±میلی‌متر).&lt;o:p /&gt;&lt;/span&gt;&lt;/font&gt;&lt;/p&gt;

&lt;p class=&quot;MsoNormal&quot; dir=&quot;rtl&quot; style=&quot;margin-bottom: 0.0001pt line-height: normal direction: rtl unicode-bidi: embed&quot;&gt;&lt;font face=&quot;tahoma, arial, helvetica, sans-serif&quot;&gt;&lt;b&gt;&lt;span lang=&quot;FA&quot;&gt;نتیجه‌گیری:&lt;/span&gt;&lt;/b&gt;&lt;span lang=&quot;FA&quot;&gt; با استفاده از پروتز
پی‌تی‌بی سوپراکندیلار با تعلیق پنوماتیک حرکت پیستونی کاهش می‌یابد. &lt;/span&gt;&lt;span dir=&quot;ltr&quot; style=&quot;font-size: 11pt color: red&quot;&gt;&lt;o:p /&gt;&lt;/span&gt;&lt;/font&gt;&lt;/p&gt;

&lt;p class=&quot;MsoNormal&quot; dir=&quot;rtl&quot; style=&quot;margin-bottom: 0.0001pt line-height: normal direction: rtl unicode-bidi: embed&quot;&gt;&lt;span lang=&quot;FA&quot;&gt;&lt;!--stripped--&gt;&lt;font face=&quot;tahoma, arial, helvetica, sans-serif&quot;&gt; &lt;/font&gt;&lt;!--stripped--&gt;&lt;/span&gt;&lt;/p&gt;

&lt;p class=&quot;MsoNormal&quot; dir=&quot;rtl&quot; style=&quot;margin-bottom: 0.0001pt line-height: normal direction: rtl unicode-bidi: embed&quot;&gt;&lt;br&gt;&lt;/p&gt;</abstract_fa>
	<abstract>&lt;p class=&quot;MsoNormal&quot; dir=&quot;ltr&quot; style=&quot;margin-bottom: 0.0001pt line-height: normal&quot;&gt;&lt;b&gt;&lt;span style=&quot;font-size: 11pt font-family: 'Times New Roman', serif&quot;&gt;Aims:&lt;/span&gt;&lt;/b&gt;&lt;span style=&quot;font-size: 11pt font-family: 'Times New Roman', serif&quot;&gt; Below the
knee amputation is the most common of lower limb amputations.&lt;/span&gt; &lt;span style=&quot;font-size: 11pt font-family: 'Times New Roman', serif&quot;&gt;The suspension system of the below the knee prostheses,
is an important&lt;/span&gt; &lt;span style=&quot;font-size: 11pt font-family: 'Times New Roman', serif&quot;&gt;component of
it.&lt;/span&gt; &lt;span style=&quot;font-size: 11pt font-family: 'Times New Roman', serif&quot;&gt;The aim of this study was
to compare the piston movement of two types of prostheses including &quot;conventional
supracondylar PTB&quot; and &quot;supracondylar PTB with pneumatic
suspension&quot; in the unilateral below the knee amputee.&lt;o:p /&gt;&lt;/span&gt;&lt;/p&gt;

&lt;p class=&quot;MsoNormal&quot; dir=&quot;ltr&quot; style=&quot;margin-bottom: 0.0001pt line-height: normal&quot;&gt;&lt;b&gt;&lt;span style=&quot;font-size: 11pt font-family: 'Times New Roman', serif&quot;&gt;Patient &amp; Methods:&lt;/span&gt;&lt;/b&gt; &lt;span style=&quot;font-size: 11pt font-family: 'Times New Roman', serif&quot;&gt;This simple quasi-experimental study was done in the Rehabilitation
Clinic of Orthotics and Prosthetics Department of Iran Rehabilitation Sciences
School, inviting the unilateral below the knee amputee in 2014. After
air-cushion designing and manufacturing process, the piston movement of a
conventional supracondylar PTB prostheses and supracondylar PTB prosthesis with
pneumatic suspension was measured using imaging and markers in 4-step constant
loading test including full weight bearing, semi-weight bearing, non-weight
bearing and the 30N loading.&lt;o:p /&gt;&lt;/span&gt;&lt;/p&gt;

&lt;p class=&quot;MsoNormal&quot; dir=&quot;ltr&quot; style=&quot;margin-bottom: 0.0001pt line-height: normal&quot;&gt;&lt;b&gt;&lt;span style=&quot;font-size: 11pt font-family: 'Times New Roman', serif&quot;&gt;Findings:&lt;/span&gt;&lt;/b&gt;&lt;span style=&quot;font-size: 11pt font-family: 'Times New Roman', serif&quot;&gt; The
mean vertical movement of the markers in conventional prostheses in non-weight
bearing was ±15mm, whereas this value &lt;/span&gt;&lt;span style=&quot;font-size: 11pt font-family: 'Cambria Math', serif&quot;&gt;​​&lt;/span&gt;&lt;span style=&quot;font-size: 11pt font-family: 'Times New Roman', serif&quot;&gt;decreased in the
pneumatic prostheses (5&lt;/span&gt;&lt;span style=&quot;font-size: 11pt font-family: 'Times New Roman', serif&quot;&gt;±&lt;/span&gt;&lt;span style=&quot;font-size: 11pt font-family: 'Times New Roman', serif&quot;&gt;mm).&lt;/span&gt; &lt;span style=&quot;font-size: 11pt font-family: 'Times New Roman', serif&quot;&gt;The mean vertical movement of the markers following 3kg loading in the
conventional prostheses was 20±mm while it decreased in the pneumatic
prostheses (10±mm).&lt;o:p /&gt;&lt;/span&gt;&lt;/p&gt;

&lt;p class=&quot;MsoNormal&quot; dir=&quot;ltr&quot; style=&quot;margin-bottom: 0.0001pt line-height: normal&quot;&gt;&lt;b&gt;&lt;span style=&quot;font-size: 11pt font-family: 'Times New Roman', serif&quot;&gt;Conclusion:&lt;/span&gt;&lt;/b&gt;&lt;span style=&quot;font-size: 11pt font-family: 'Times New Roman', serif&quot;&gt; Piston
movement decreased using the supracondylar PTB prostheses with pneumatic
suspension.&lt;o:p /&gt;&lt;/span&gt;&lt;/p&gt;

&lt;p class=&quot;MsoNormal&quot; dir=&quot;ltr&quot; style=&quot;margin-bottom: 0.0001pt line-height: normal&quot;&gt;&lt;span style=&quot;font-size: 11pt font-family: 'Times New Roman', serif&quot;&gt;&lt;!--stripped--&gt; &lt;!--stripped--&gt;&lt;/span&gt;&lt;/p&gt;

&lt;p class=&quot;MsoNormal&quot; dir=&quot;ltr&quot; style=&quot;margin-bottom: 0.0001pt line-height: normal&quot;&gt;&lt;br&gt;&lt;/p&gt;</abstract>
	<keyword_fa>پروتز زیر زانو, تعلیق پروتزی, حرکت پیستونی</keyword_fa>
	<keyword>Prosthesis Implantation, Rehabilitation, Knee, Amputees</keyword>
	<start_page>227</start_page>
	<end_page>231</end_page>
	<web_url>http://ijwph.ir/browse.php?a_code=A-10-1097-1&amp;slc_lang=fa&amp;sid=1</web_url>


<author_list>
	<author>
	<first_name></first_name>
	<middle_name></middle_name>
	<last_name>Haji Aghayi B.</last_name>
	<suffix></suffix>
	<first_name_fa>بهنام </first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>حاجی آقایی</last_name_fa>
	<suffix_fa></suffix_fa>
	<email>bhajiaghaei@yahoo.com</email>
	<code>1530031947532846008334</code>
	<orcid>1530031947532846008334</orcid>
	<coreauthor>Yes
</coreauthor>
	<affiliation>Rehabilitation Department, Rehabilitation Sciences Faculty, Iran University of Medical Sciences, Tehran, Iran</affiliation>
	<affiliation_fa>دانشکده علوم توانبخشی، دانشگاه علوم پزشکی ایران</affiliation_fa>
	 </author>


	<author>
	<first_name></first_name>
	<middle_name></middle_name>
	<last_name>Anoushe S.Z.</last_name>
	<suffix></suffix>
	<first_name_fa>سیده زهرا</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>انوشه</last_name_fa>
	<suffix_fa></suffix_fa>
	<email></email>
	<code>1530031947532846008335</code>
	<orcid>1530031947532846008335</orcid>
	<coreauthor>No</coreauthor>
	<affiliation>Rehabilitation Department, Rehabilitation Sciences Faculty, Iran University of Medical Sciences, Tehran, Iran</affiliation>
	<affiliation_fa>گروه توانبخشی، دانشکده علوم توانبخشی، دانشگاه علوم پزشکی ایران، تهران، ایران</affiliation_fa>
	 </author>


	<author>
	<first_name></first_name>
	<middle_name></middle_name>
	<last_name>Sa’eidi H.</last_name>
	<suffix></suffix>
	<first_name_fa>حسن</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>سعیدی</last_name_fa>
	<suffix_fa></suffix_fa>
	<email></email>
	<code>1530031947532846008336</code>
	<orcid>1530031947532846008336</orcid>
	<coreauthor>No</coreauthor>
	<affiliation>Rehabilitation Department, Rehabilitation Sciences Faculty, Iran University of Medical Sciences, Tehran, Iran</affiliation>
	<affiliation_fa>گروه توانبخشی، دانشکده علوم توانبخشی، دانشگاه علوم پزشکی ایران، تهران، ایران</affiliation_fa>
	 </author>


	<author>
	<first_name></first_name>
	<middle_name></middle_name>
	<last_name>Gholizadeh H.</last_name>
	<suffix></suffix>
	<first_name_fa>حسین</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>قلیزاده</last_name_fa>
	<suffix_fa></suffix_fa>
	<email></email>
	<code>1530031947532846008337</code>
	<orcid>1530031947532846008337</orcid>
	<coreauthor>No</coreauthor>
	<affiliation>Biomedical Engineering Department, Engineering Faculty, Malaya University, Kuala Lampur, Malaysia  </affiliation>
	<affiliation_fa>گروه مهندسی بیومدیکال، دانشکده مهندسی، دانشگاه مالایا، کوالالامپور، مالزی</affiliation_fa>
	 </author>


</author_list>


	</article>
</articleset>
</journal>
